toshiba mmy-map1404ft8-e service manual Archived Forum Post

Index of archived forum posts

Question:

Toshiba Mmy-map1404ft8-e Service Manual Online

Dec 16 '15 at 12:28

I have been unsuccessful at getting past sp_OACreate under SqlServer 2012. The same sproc works on a SqlServer 2008 box.

EXEC @hr = sp_OACreate 'Chilkat.Crypt2', @crypt OUT results in -2147221005 for @hr.

Callig get error: EXEC @HR = sp_OAGetErrorInfo @crypt, @Source OUT, @Description OUT;

results in @Description being "Invalid class string".

I have checked the registry, the clsids are there. I even edited permission on crypt2 and crypt2.1 adding full control to everyone. I also verified the DLL's folder has everyone read/exec permissions.

I am at a loss here.


Answer

See the online reference documentation for the correct strings to pass to sp_OACreate. See http://www.chilkatsoft.com/refdoc/xChilkatCrypt2Ref.html

Toshiba Mmy-map1404ft8-e Service Manual Online

Three highly efficient, inverter-driven DC twin-rotary compressors Electrical Profile: 3-Phase, 380V–415V, 50Hz power supply

Supports up to 500 meters of total pipe length and up to 40 meters of vertical lift 🛠️ Key Technical Sections of the Service Manual toshiba mmy-map1404ft8-e service manual

Height: 1800mm, Width: 990mm, Depth: 750mm. Net operating weight rests at approximately 263 kg . Layout and Component Navigation The manual details line voltage routings, communication bus

| Display Code | Description | Probable Cause | |--------------|-------------|----------------| | | Inverter compressor IPM protection | Overcurrent, short circuit, or compressor lock | | P12 | Outdoor fan motor error | Locked rotor or Hall IC failure | | F03 | Discharge temperature too high | Low refrigerant charge, clogged filter, or faulty thermistor | | L30 | Communication error between indoor and outdoor units | Wiring mismatch, noise interference, or PCB failure | | E10 | Pressure sensor fault | Open or short circuit in high/low pressure sensor | "Entropy_Watcher is messing with me."

(for the SMMS‑i series) – for in‑depth troubleshooting and repair.

The MMY-MAP1404FT8-E features an integrated electronics bay houses three distinct compressor Inverter P.C. Boards (MCC-1746) and fan Inverter P.C. Boards (MCC-1734). The manual details line voltage routings, communication bus networks (2-core screened cable wiring connecting indoor and outdoor frames), and grounding connections. 2. Refrigerant Flow & Cycle Diagrams

"This can't be real," he said. "Entropy_Watcher is messing with me."


Answer

It is so that a future version of the ActiveX can co-exist with older versions. You've heard of DLL hell, right? The current naming of "Chilkat_9_5_0." has not changed for several YEARS. Eventually, Chilkat will do a major update to rid itself of all deprecated methods and make long-needed changes which break backward compatibility. When doing so, the name will change -- this will make it so that new programs can use the new version WITHOUT breaking existing older applications.


Answer

What about 9.4.x? Did it use the Chilkat.Crypt2 naming? If so, is there a download for it?